ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V
IN
= 2V to 3.6V, C1 = C2 = 0.22
µ
F, C3 = C4 = 10µF, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.)
Note 1:
The MAX619 is not short-circuit protected.
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
No-Load Supply Current
75
170
µ
A
0.02
1
Shutdown Supply
Current
10
µ
A
82
Input Voltage
V
IN
2
3.6
V
82
80
Efficiency
Eff
%
Switching Frequency
500
kHz
V
IH
0.7 x V
IN
SHDN Input Threshold
V
IL
0.4
V
±1
SHDN Input Current
I
IH
±10
µ
A
CONDITIONS
V
IN
= 3V, I
OUT
= 30mA
2V
≤
V
IN
≤
3.6V, I
OUT
= 0mA
V
IN
= 2V, I
OUT
= 20mA
2V
≤
V
IN
≤
3.6V, I
OUT
= 0mA,
V
SHDN
= V
IN
V
IN
= 3V, I
OUT
= 20mA
At full load
V
SHDN
= V
IN
V
IN
to GND ............................................................-0.3V to +5.5V
V
OUT
to GND .........................................................-0.3V to +5.5V
SHDN to GND ..............................................-0.3V to (V
IN
+ 0.3V)
I
OUT
Continuous (Note 1)..................................................120mA
Continuous Power Dissipation (T
A
= +70°C)
Plastic DIP (derate 9.09mW/°C above +70°C) ............727mW
SO (derate 5.88mW/°C above +70°C) .........................471mW
CERDIP (derate 8.00mW/°C above +70°C) .................640mW
Operating Temperature Ranges
MAX619C_ _ .......................................................0°C to +70°C
MAX619E_ _ ....................................................-40°C to +85°C
MAX619MJA ..................................................-55°C to +125°C
Storage Temperature Range .............................-65°C to +165°C
Lead Temperature (soldering, 10sec) .............................+300°C
MAX619C/E
MAX619M
MAX619C/E
MAX619M
I
IN
2.0V
≤
V
IN
≤
3.6V, 0mA
≤
I
OUT
≤
20mA
3.0V
≤
V
IN
≤
3.6V, 0mA
≤
I
OUT
≤
50mA, MAX619C
3.0V
≤
V
IN
≤
3.6V, 0mA
≤
I
OUT
≤
45mA, MAX619E
Output Ripple
V
RIPPLE
100
mV
No load to full load
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
3.0V
≤
V
IN
≤
3.6V, 0mA
≤
I
OUT
≤
40mA, MAX619M
Output Voltage
V
OUT
4.8
5.0
5.2
V