Table 3. configuration register bit descriptions, Table 4. resolution configuration, Table 5. fault tolerance configuration – Rainbow Electronics DS75LV User Manual
Page 8

DS75LV: Digital Thermometer and Thermostat
8
of
13
Table 3. Configuration Register Bit Descriptions
BIT NAME
FUNCTIONAL DESCRIPTION
0
Reserved
Power-up state = 0
The master can write to this bit, but it will always read out as a 0.
R1
Conversion Resolution Bit 1
Power-up state = 0
Sets conversion resolution (see Table 5)
R0
Conversion Resolution Bit 0
Power-up state = 0
Sets conversion resolution (see Table 5)
F1
Thermostat Fault Tolerance Bit 1
Power-up state = 0
Sets the thermostat fault tolerance (see Table 6).
F0
Thermostat Fault Tolerance Bit 0
Power-up state = 0
Sets the thermostat fault tolerance (see Table 6).
POL
Thermostat Output (O.S.) Polarity
Power-up state = 0
POL = 0 — O.S. is active low.
POL = 1 — O.S. is active high.
TM
Thermostat Operating Mode
Power-up state = 0
TM = 0 — Comparator mode.
TM = 1 — Interrupt mode.
See the OPERATION–Thermostat section for a detailed description of
these modes.
SD
Shutdown
Power-up state = 0
SD = 0 — Active conversion and thermostat operation.
SD = 1 — Shutdown mode.
See the SHUTDOWN MODE section for a detailed description of this
mode.
Table 4. Resolution Configuration
R1 R0
THERMOMETER
RESOLUTION
MAX CONVERSION
TIME
0 0
9-bit
150ms
0 1
10-bit
300ms
1 0
11-bit
600ms
1 1
12-bit
1200ms
Table 5. Fault Tolerance Configuration
F1 F0
CONSECUTIVE OUT-OF-LIMITS
CONVERSIONS TO TRIGGER O.S.
0 0
1
0 1
2
1 0
4
1 1
6