Shift register mode timing waveforms, Ac testing input/output waveforms(1), Float waveforms(1) – Rainbow Electronics AT89C4051 User Manual
Page 14: Float waveforms
14
AT89C4051
1001D–06/01
Shift Register Mode Timing Waveforms
AC Testing Input/Output Waveforms
Note:
1. AC Inputs during testing are driven at V
CC
- 0.5V for a logic 1 and 0.45V for a logic 0. Timing measurements are made at V
IH
min. for a logic 1 and V
IL
max. for a logic 0.
Float Waveforms
Note:
1. For timing purposes, a port pin is no longer floating when a 100 mV change from load voltage occurs. A port pin begins to
float when 100 mV change frothe loaded V
OH
/V
OL
level occurs.
Serial Port Timing: Shift Register Mode Test Conditions
V
CC
= 5.0V
± 20%; Load Capacitance = 80 pF
Symbol
Parameter
12 MHz Osc
Variable Oscillator
Units
Min
Max
Min
Max
t
XLXL
Serial Port Clock Cycle Time
1.0
12t
CLCL
µs
t
QVXH
Output Data Setup to Clock Rising Edge
700
10t
CLCL
-133
ns
t
XHQX
Output Data Hold after Clock Rising Edge
50
2t
CLCL
-117
ns
t
XHDX
Input Data Hold after Clock Rising Edge
0
0
ns
t
XHDV
Clock Rising Edge to Input Data Valid
700
10t
CLCL
-133
ns