Cha data output termination control (04h), Chb data output termination control (05h) – Rainbow Electronics MAX19516 User Manual
Page 21

MAX19516
Dual-Channel, 10-Bit, 100Msps ADC
______________________________________________________________________________________
21
CHA Data Output Termination Control (04h)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
X
X
CT_DCLK_2_A
CT_DCLK_1_A
CT_DCLK_0_A
CT_DATA_2_A
CT_DATA_1_A
CT_DATA_0_A
Bit 7, 6
Don’t care
Bit 5, 4, 3
CT_DCLK_2_A, CT_DCLK_1_A, CT_DCLK_0_A: CHA DCLK termination control
000 = 50Ω (default)
001 = 75Ω
010 = 100Ω
011 = 150Ω
1xx = 300Ω
Bit 2, 1, 0
CT_DATA_2_A, CT_DATA_1_A, CT_DATA_0_A: CHA data output termination control
000 = 50Ω (default)
001 = 75Ω
010 = 100Ω
011 = 150Ω
1xx = 300Ω
CHB Data Output Termination Control (05h)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
X
X
CT_DCLK_2_B
CT_DCLK_1_B
CT_DCLK_0_B
CT_DATA_2_B
CT_DATA_1_B
CT_DATA_0_B
Bit 7, 6
Don’t care
Bit 5, 4, 3
CT_DCLK_2_B, CT_DCLK_1_B, CT_DCLK_0_B: CHB DCLK termination control
000 = 50Ω (default)
001 = 75Ω
010 = 100Ω
011 = 150Ω
1xx = 300Ω
Bit 2, 1, 0
CT_DATA_2_B, CT_DATA_1_B, CT_DATA_0_B: CHB data output termination control
000 = 50Ω (default)
001 = 75Ω
010 = 100Ω
011 = 150Ω
1xx = 300Ω