Rainbow Electronics MAX6662 User Manual
Page 5

MAX6662
12-Bit + Sign Temperature Sensor with
SPI-Compatible Serial Interface
_______________________________________________________________________________________
5
For example: If T
HIGH
is set to 100°C and T
HYST
is set
to 20°C,
ALERT does not assert until temperature
exceeds 100°C. If the temperature is then read through
the serial interface,
ALERT deasserts. ALERT asserts
again when temperature is less than 80°C (Figure 2).
Comparator Mode
In the comparator mode,
ALERT is asserted when tem-
perature exceeds the value in the T
HIGH
register, or is
lower than the value in the T
LOW
register.
ALERT
deasserts when temperature is less than T
HIGH
- T
HYST
or greater than T
LOW
+ T
HYST
. Reading the registers
does not deassert
ALERT.
For example: If T
HIGH
is set to 100°C and T
LOW
is set
to 80°C,
ALERT does not assert until temperature
exceeds 100°C, or is below 80°C. Then,
ALERT only
deasserts if temperature is less than T
HIGH
- T
HYST
or
greater than T
LOW
+ T
HYST
.
Overtemperature Alert
OT operates only in comparator mode. The OT pin is
asserted when the temperature exceeds T
MAX
, and
deasserted when the temperature drops below
T
MAX
- T
HYST
. A read operation does not reset
OT.
OT is an open-drain active-low (default) output, but can
be programmed to active-high.
TEMPERATURE
OT
SERIAL INTERFACE
V
CC
SIO
SCLK
CONFIGURATION
CS
ALERT
T
LOW
T
HIGH
T
MAX
T
HYST
12 -BIT
+ SIGN
ADC
Figure 1. MAX6662 Simplified Functional Diagram
T
HIGH
- T
HYST
T
HIGH
T
LOW
T
LOW
+ T
HYST
ALERT
TEMPERATURE
LAST INTERRUPT MISSED, BUT
THRESHOLD STILL CHANGES TO T
HIGH
.
*
*
*
* TEMPERATURE READ
Figure 2. Example of
ALERT
Operation in Interrupt Mode