MAX6641

SMBus-Compatible Temperature Monitor with
Automatic PWM Fan-Speed Controller

10

______________________________________________________________________________________

BIT

NAME

POR STATE

FUNCTION

7

0

Reserved. Set to zero.

6

0

Reserved. Set to zero.

5

TIMEOUT

0

Set TIMEOUT to zero to enable SMBus timeout for
prevention of bus lockup. Set to 1 to disable this function.

4

FAN PWM INVERT

0

Set FAN PWM INVERT to zero to force PWMOUT low when
the duty cycle is 100%. Set to 1 to force PWMOUT high
when the duty cycle is 100%.

3

MIN DUTY CYCLE

0

Set MIN DUTY CYCLE to zero for a 0% duty cycle when
the measured temperature is below the fan-temperature
threshold in automatic mode. When the temperature
equals the fan-temperature threshold, the duty cycle is the
value in the fan-start duty-cycle register, which increases
with increasing temperature.
Set MIN DUTY CYCLE to 1 to force the PWM duty cycle to
the value in the fan-start duty-cycle register when the
measured temperature is below the fan-temperature
threshold. As the temperature increases above the
temperature threshold, the duty cycle increases as
programmed.

2

SPIN-UP DISABLE

0

Set SPIN-UP DISABLE to 1 to disable spin-up. Set to zero
for normal fan spin-up.

1

X

Don’t care.

0

X

Don’t care.

Table

2. Configuration Byte Definition (02h)

OT

Mask (06h)

Set bit D7 to 1 in the OT mask register to prevent the
OT output from asserting on faults in the remote-diode
temperature channel. Set bit D6 to 1 to prevent the OT
output from asserting on faults in the local-diode tem-
perature channel. The POR state of the OT mask regis-
ter is 00h.

Fan-Start Duty Cycle (07h)

The fan-start duty-cycle register determines the PWM
duty cycle where the fan starts spinning. Bit D3 in the
configuration byte register (MIN DUTY CYCLE) deter-
mines the starting duty cycle. If the MIN DUTY CYCLE
bit is 1, the duty cycle is the value written to the fan-
start duty-cycle register at all temperatures below the
fan-start temperature. If the MIN DUTY CYCLE bit is
zero, the duty cycle is zero below the fan-start tempera-
ture and has this value when the fan-start temperature
is reached. A value of 240 represents 100% duty cycle.
Writing any value greater than 240 causes the fan
speed to be set to 100%. The POR state of the fan-start
duty-cycle register is 60h, 40%.

Fan Maximum Duty Cycle (08h)

The fan maximum duty-cycle register sets the maxi-
mum allowable PWMOUT duty cycle between 2/240
(0.83% duty cycle) and 240/240 (100% duty cycle).
Any values greater than 240 are recognized as 100%
maximum duty cycle. The POR state of the fan maxi-
mum duty-cycle register is F0h, 100%. In manual con-
trol mode, this register is ignored.

Fan-Target Duty Cycle (09h)

In automatic fan-control mode, this register contains the
present value of the target PWM duty cycle, as deter-
mined by the measured temperature and the duty-
cycle step size. The actual duty cycle needs a settling
time before it equals the target duty cycle if the duty-
cycle rate of change register is set to a value other than
zero. The actual duty cycle needs the time to settle as
defined by the value of the duty-cycle rate-of-change
register; therefore, the target duty cycle and the actual
duty cycle are often different. In manual fan-control
mode, write the desired value of the PWM duty cycle
directly into this register. The POR state of the fan-tar-
get duty-cycle register is 00h.