Troubleshooting - timer – Peerless Water 30 FME-XTR Series - Service-Owners Manual User Manual
Page 12
Page 11
Troubleshooting - Timer
If an error is detected, an error screen will alternate with the main display screen every few seconds, and the LED
light will be red.
During an error condition, the unit continues to monitor the flow meter and update the remaining capacity.
Once an error condition is corrected, the unit returns to the operating status it was in prior to the error, and
regeneration resumes according to normal programming. If an error is cleared by reprogramming the unit in
the Master Programming Mode, the volume remaining may be reset to the full unit capacity (as though it had
just regenerated). If an error is present, a regeneration can only occur manually by pressing and holding the
Extra Cycle button for 5 seconds. If the unit was in regeneration when the error occurred, it will complete the
regeneration cycle and go into service.
When the problem is corrected, and the error no longer displays (it may take several seconds for the unit to stop
displaying the error message), the unit will return to normal operation. The LED light will no longer be red, and
will turn Green if the unit is regenerating, or Blue if the unit is in service.
Problem
Correction
A. Flashing/blinking display
A. Power outage has occurred. Either wait 5 minutes for
blinking to stop, or press any key on the keypad.
B. Unit not responding after going into
regeneration
B. Verify the unit is configured correctly (ex: wiring valve
type). Perform a Master Reset by holding the Shift button and
cycling power. Check and verify the choices selected in Master
Programming Mode.
C. Unit displays “ERROR CODE: REPLACE
UNIT” (corrupted UAP)
C. Contact your local water treatment professional.
Error Codes
Error
Code
Display Message
Correction
01
ERROR CODE:
PROGRAM UNIT
Go through all screens in Master Programming Mode.
02
ERROR CODE:
PROGRAM UNIT
Go through all screens in Master Programming Mode.
03
ERROR CODE:
SERVICE UNIT
Perform a Master Reset by holding the Shift button and cycling power. Go through
all screens in Master Programming Mode. Manually initiate a regeneration cycle
by pressing the Extra Cycle button for 5 seconds.
04
ERROR CODE:
SERVICE UNIT
Perform a Master Reset by holding the Shift button and cycling power. Go through
all screens in Master Programming Mode. Manually initiate a regeneration cycle
by pressing the Extra Cycle button for 5 seconds.
05
ERROR CODE:
SERVICE UNIT
Call your local water treatment professional as soon as possible. Leave the unit
running (do not unplug).
NOTE: If the above corrections do not work, please contact your local water treatment professional.
Error Display Screen Examples