05.

Fire-fighting measures

5.1 Suitable extinguishing media
CO2; Extinction powder; Foam Water; jet spray; Cool container at risk with water.
5.2 Extinguishing media which shall not be used for safety reasons
High volume water jet
5.3 Special exposure hazards arising from the substance or preparation itself, combustion
products, resulting gases
In case of fire the following can develop:
Oxides of carbon; Toxic pyrolysis products; Danger of bursting (explosion) when heated
5.4 Special protective equipment for fire-fighters
In case of fire and/or explosion do not breathe fumes. Protective respirator with independent air supply.
According to size of fire Full protection, if necessary
5.5 Further information
Dispose of contaminated extinction water according to official regulations.

06. Accidental release measures

Refer to point 13. and for personal protection refer to point 8.
6.1 Personal precautions
Ensure sufficient supply of air. Avoid inhalation, and contact with eyes or skin. If applicable, caution - risk of
slipping
6.2 Environmental precautions
If leakage occurs, dam up. Prevent surface and ground-water infiltration, as well as ground penetration. Prevent
from entering drainage system.
6.3 Methods for cleaning up
Collect using absorbant material (e.g. Universal binding medium), and dispose of according to point 13.
Or:
Allow product to harden. Collect mechanically and dispose of according to point 13.

07.

Handling and storage

7.1 Handling
Tips for safe handling:
See point 6.1
Ensure good ventilation. Keep away from sources of ignition - Do not smoke. Eating, drinking, smoking, as well
as food-storage, is prohibited in work-room. Observe directions on label and instructions for use.
7.2. Storage
Requirements for storage rooms and containers:
Do not store with oxidizing agents. Not to be stored in gangways or stair wells. Store product closed and only in
original packing. Observe special regulations for aerosols!
Special storage conditions:
See point 10
Protect against moisture and store closed. Keep protected from direct sunlight and temperatures over 50°C.
Store in a well ventilated place.

08.

Exposure controls/personal protection

Chemical Name

content%:

WEL-STEL: ---

Other informations: ---

WEL-TWA: 10 ppm (25 mg/m3) (EC)

---

Acetic Acid

BMGV: ---

WEL-TWA = Workplace Exposure Limit - Long-term exposure limit (8-hour TWA (= time weighted average) reference period)
EH40. AGW = "Arbeitsplatzgrenzwert" (workplace limit value, Germany). | WEL-STEL =Workplace Exposure Limit - Short-terme
exposure limit (15-minute reference period). | BMGV = Biological monitoring guidance value EH40. BGW = "Biologischer
Grenzwert" (biological limit value, Germany) | Other information: Sen = Capable of causing occupational asthma. Sk = Can be
absorbed through skin. Carc = Capable of causing cancer and/or heritable genetic damage. ** = The exposure limit for this
substance is repealed through the TRGS 900 (Germany) of January 2006 with the goal of revision.

Gasket Maker

This manual is related to the following products: