SCT-Germany EXTRA GETRIEBEOEL SAE 75W-90 API GL 5 User Manual
Material safety data sheet
MATERIAL SAFETY DATA SHEET
Page 1/1
Printing Date 28.05.2004
Reviewed on 26.02.2003
1. Identification of the substance/preparation and of the company/undertaking
· Product details
MANNOL EXTRA GETRIEBEOEL
SAE 75W-90, API GL-5
· Manufacturer/Supplier: SCT-Vertriebs GmbH
Feldstrasse 154
22880 Wedel/Hamburg
Tel. +49(0) 4103-12 11-110 Fax. +49(0) 4103-12 11-116
Information provided by / Phone: +49(0) 4103-12 11-113
Emergency telephone number: +49(0) 4103-12 11-10
· Further information obtainable from: Product safety department.
2. Composition/information on ingredients
· Chemical characterization
· Description: Mixture of substances listed below with nonhazardous additions.
Dangerous components: olefin sulfide (53) 2.5-10 % R 53
phosphoric acid ester amine salt 1.0-2.5 % N; R 51/53
· Additional information: For the wording of the listed risk phrases refer to section 16.
3. Hazards identification
· Hazard description: Not applicable.
· Information concerning particular hazards for human and environment: The product does not
have to be labelled due to the calculation procedure of the "General Classification guideline for
preparations of the EU" in the latest valid version.
· Classification system: The classification is according to the latest editions of the EU-lists, and
extended by company and literature data.
4. First-aid measures
· General information: No special measures required.
· After inhalation: Supply fresh air; consult doctor in case of complaints.
· After skin contact: Generally the product does not irritate the skin.
· After eye contact: Rinse opened eye for several minutes under running water.
· After swallowing: If symptoms persist consult doctor.
5. Fire-fighting measures
· Suitable extinguishing agents: Use fire extinguishing methods suitable to surrounding
conditions.
· Protective equipment: No special measures required.
6. Accidental release measures
· Person-related safety precautions: Not required.
· Measures for environmental protection: Do not allow to enter sewers/ surface or ground water.