background image

06. Accidental release measures

07.

Handling and storage

Prepared according to Annex II of EC Regulation 1907/2006

Super Glue

05.

Fire-fighting measures

5.1 Suitable extinguishing media

CO2
Water jet spray
Extinction powder
Large fire:
Water jet spray
Alcohol resistant foam
Cool container at risk with water.

5.2 Extinguishing media w hich shall not be used for safety reasons

n.c.

5.3 Special exposure hazards arising from the substance or preparation itself,
combustion products, resulting gases

In case of fire the following can develop:
Toxic gases
Oxides of carbon
Oxides of nitrogen

5.4 Special protective equipment for fire-fighters

Protective respirator with independent air supply
According to size of fire
Full protection, if necessary

5.5 Further information

Dispose of contaminated extinction water according to official regulations.

Refer to point 13. and for personal protection refer to point 8.

6.1 Personal precautions

Ensure sufficient supply of air.
Avoid inhalation, and contact with eyes or skin.

6.2 Environmental precautions

If leakage occurs, dam up.
Prevent from entering drainage system.
Prevent surface and ground-water infiltration, as well as ground penetration.

6.3 Methods for cleaning up

Collect using absorbant material (e.g. Universal binding medium), and dispose of according to point 13.
Flush residue using copious water.

7.1 Handling

Tips for safe handling:

See point 6.1
Ensure good ventilation.Keep away from sources of ignition - Do not smoke. Wash hands before breaks and at end of work.
Handle and open container with care.
Observe directions on label and instructions for use.Use working methods according to operating instructions. During
processing: Ambient humidity should be increased to at least 50-60% relative humidity.

7.2. Storage Requirements for storage rooms and containers:

Not to be stored in gangways or stair wells.Store product closed and only in original packing. Do not store with alkalis. Do
not store with acids. Do not store with oxidizing agents.

Special storage conditions:

See point 10
Protect against moisture and store closed.Protect from direct sunlight and warming. Only store at temperatures from 5°C to
25°C

08.

Exposure controls/personal protection

Chemical Name

Ethyl 2-cyanoacrylate

WEL-TWA: ---

WEL-STEL: 0,3ppm (1,5 mg/m³)

---

BMGV: ---

Other informations: ---

Printing Date: 29.11.2010

Revision Date: 29.11.2010