Material safety data sheet – SCT-Germany DEXRON III AUTOMATIC PLUS User Manual
Page 2
MATERIAL SAFETY DATA SHEET
Page 2/2
Printing Date 28.05.2004
Reviewed on 16.02.2003
After spillage and/or leakage : Spill area may be slippery. Dike for recovery or absorb with
appropriate material.
Use suitable disposal containers.
7. Handling and storage
General : No naked flames. No smoking.
Storage : Store in dry, well-ventilated area.
Keep at temperature not exceeding 40°C
Handling : Wash hands and other exposed areas with mild soap and water before eating,
drinking or smoking or when leaving work.
Transport temperature : Keep at temperature not exceeding 40°C
8. Exposure controls / personal protection
Personal protection
- Respiratory protection : No special respiratory protection equipment is recommended under
normal
conditions of use with adequate ventilation.
- Skin protection : No special clothing/skin protection equipment is recommended under normal
conditions of use.
- Eye protection : Goggles.
- Ingestion : When using, do not eat, drink or smoke.
Industrial hygiene : No special protection required where adequate ventilation is maintained.
9. Physical and chemical properties
Physical state : Oily liquid.
Colour : Red.
Odour : Oil.
pH value : Not applicable.
Density [g/dm³] : 858
Vapour density (101.3 kPa/air=1) : >12
Viscosity at 40°C [mm2/s] : 33
Solubility in water : Negligible.
Flash point [°C] (ASTM D 92) : >196
Auto-ignition temperature [°C] : No data available.
Explosion limits (vol% in air) : LEL: 1.0
UEL: 6.0
Log P octanol / water at 20°C : No data available.
10. Stability and reactivity
Hazardous decomposition products : None under normal conditions.
Hazardous reactions : None under normal conditions.
Hazardous properties : None under normal conditions.
Materials to avoid : Strong oxidizers.
Acids.
Bases.
11. Toxicological information
Rat oral LD50 [mg/kg] : No data available.
Inhalation : Neglegible hazard at ambient/normal handling temperatues.