PNEG-218 30' Cor-Lok and Cut-Lok Flooring

11. Air Flow Support Instructions

Notes:

1. Use a maximum spacing of 16" for perforated corrugated flooring.

2. The number of supports listed is based on the maximum peaked capacity of each bin.

3. Use extra single supports for split floors.

4. Extra supports are required for grain recirculating equipment. Use the manufacturer’s

recommendation for the number and spacing of extra supports. NOTE: For Grain Flows, Air Flow
Supports are doubled in a 14' diameter in the center of the floor.

5. Contact a representative for air flow supports required for larger bins and deeper grain depths.

6. *Increase the number of supports by 5% when used with 6-3/4" wide mfs floor planks.

Figure 11B