beautypg.com

Danze D562040 - Installation Manual User Manual

Page 7

background image

®

6

7.3

A.

B.

C.

Reinstall thermostatic handle assembly.

Turn off the volume control handle clockwise.

Reinstall temperature selector handle. The temperature

limit over-ride button should align the gun sight on limit

stop.

Install the screw in the thermostatic handle and

tighten it by hex wrench (supplied), then attach

the handle cap.

Over-ride button is in line with the gun sight.

7.2-C Resetting Maximum Output Temperature of Valve

1) Turn off the volume control

2) Return the handle position to the High Temp Over-Ride Position.

3) Remove the Handle Assembly (Figure 7.1)

4) Rotate the cartridge stem clockwise by 1/8 of a turn.

5) Reinstall the Handle Assembly (Figure 7.3)

6) Check the valve maximum output temperature by following 7.2-B. If the temperature is still above your desired

temperature, repeat steps 1 through 5.

© 2008 Danze, Inc. All rights reserved.