THE MILTON NO. 825 REMOTE CONTROL AIR SWITCH IS AN AIR OPERAT E D
MOMENTARY CONTACT ELECTRICAL CONTROLLER. IT WILL OPERATE ALL MILTON
REMOTE CONTROLLED SIGNALS (MODELS 827 AND 830) AS WELL AS BELLS,
BUZZERS, LIGHTS, ETC. IT WILL ALSO OPERATE RELAYS FOR INDUSTRIAL
APPLICATIONS.
ELECTRICAL RATING
0 - 240 VOLTS AC OR DC, 10 AMPS
STANDARD HOOK-UPS
FOR
MODEL 825
OPTIONAL
STANDARD
DOORBELL OR BUZZER
SECONDARY
10 VOLTS AC
OPTIONAL
830
CHIME
825
PRIMARY
110 - 125 VOLTS AC
827
BELL
8
27
BELL
MOMENTARY
AIR SWITCH
10
AMPS MAX.
REMOVE SMALL
COVER
NOT USED
SIGNAL AIR HOSE.
PLACE ACROSS
DRIVEWAY. PLUG
UNUSED END.
110 - 125 VOLTS AC
(OR 6 - 220 VOLTS AC OR DC WITH
MATCHING VOLTAGE UNITS)
This is a pictorial wiring diagram to suggest various hook-up options and to show a
typical circuit path. Any installation must be properly terminated and insulated and must
conform to all applicable codes. Consult a qualified electrician.
NOTE: The center terminal on the terminal strip can be used as a convenient tie point if
desired.
IMPORTANT:
The model 825 must always be mounted with the hose connector tube
pointing straight down. Remove plastic cap before attaching hose.
STANDARD HOOK-UPS
FOR
RELAY APPLICATIONS
LATCHING RELAY CONNECTOR
(OPTIONAL)
RESET
(OR UNLATCH)
SWITCH N.C.
TO CIRCUIT TO
BE CONTROLLED
RELAY
USER SUPPLIED
MUST MATCH
POWER SOURCE
TO RELAY
POWER SOURCE
0 - 240 VOLTS AC OR DC
SIGNAL AIR HOSE.
PLUG UNUSED END.
10
AMPS MAX.
MOMENTARY
AIR SWITCH
(NORMALLY OPEN)
(NORMALLY OPEN)
STANDARD BELL
TRANSFORMER
825
UP TO 10 ADDITIONAL