Velleman CHLSC1 User Manual
Page 7

CHLSC1
09.09.2009
©Velleman
nv
7
•
Output brightness too low
Check the output connections and controller input voltage.
•
Overheating of the controller
Make sure the controllers’ input voltage is not too high and check whether
there is sufficient ventilation.
•
In linked mode, controllers don’t work synchronously.
Check the data terminals and the length of the data bus. Press any key on
the remote control to start synchronizing.
•
Remote control is not working
Point the remote control straight towards the IR receiver, check the
distance (<7m). Replace the battery.
10. Technical specifications
input voltage
12 or 24VDC
output power
180W (12VDC) or 360W (24VDC)
max. output for each loop
60W (12VDC) or 120W (24VDC)
IR remote control working distance
7m
dimensions
Controller
121 x 51 x 26mm
IR remote control
90 x 49 x 7mm
Weight
Controller ±110gr
IR remote control
±22gr
power supply remote control