Velleman CAMCOLD-CK User Manual
Page 4
![background image](/manuals/270697/4/background.png)
CAMCOLD/CK_v2
4
VELLEMAN
5. Keyboard manipulation
Note: Keys "AUX1", "AUX2", "F3", "F4", "MON ", "ACK " and "MSK " are invalid and will not be used. Use the "SAL"
key to clear your input.
1.
How to choose a camera:
•
Press "-1" to choose the previous camera.
•
Press "+1" to choose the next camera.
•
To choose a specific camera, press a camera number from 1-99 and then press "CAM".
2.
Pan/tilt and lens control:
•
Input a camera number from 1-99 and press "CAM". You can also choose a camera by pressing
"-1" (previous camera) or "+1" (next camera).
•
Press "I+" or "I-" to open or close the iris, press "Z+" or "Z-" to zoom in or out, press "F+" or "F-"
to focus in or out. You can also use the keyboard joystick.
•
Press "PAN" for a continuous horizontal rotation. Press "PAN" to stop or to start again
(depending on the type of camera).
3.
How to preset positions (depending on the dome camera type):
•
Move the joystick and adjust to the desired location.
•
Press "F1" and then press "8".
•
Input the preset number (1-64).
•
Press "PRE".
4.
How to view the preset positions:
a)
Manually:
•
Choose a camera by pressing a camera input number.
•
Input the pre-position number (1-64).
•
Press "CALL" to view the pre-set position and to stop.
b)
Automatically:
•
Choose a camera by pressing a camera input number (2-16). The maximum transfer length is
16.
•
Input the number of pre-positions you want to view sequentially (2-16).
•
Press "RUN".
c)
Stop the auto-touring:
•
Choose the scanning camera.
•
Press "HOLD". The camera will stop scanning and the other cameras will continue working
normally.
5.
Decoder switch control:
"AUX1" and "AUX2" are invalid.
6.
There are two methods to set the delay time:
•
Press "DWL" to add 1 unit at a time. The delay time ranges from 1 to 60 sec.
•
Input the desired delay time (with a minimum of 4) and press "DWL".
7.
Press "SAL" to reset the number previously keyed in.
8.
Address:
Standard address is on PELCO-P protocol.
Example: Camera 1 on 1
st
address (OFF, OFF, OFF, OFF, OFF, OFF)
Camera 2 on 2
nd
address (ON, OFF, OFF, OFF, OFF, OFF)
Camera 3 on 3
rd
address (OFF, ON, OFF, OFF, OFF, OFF)
Camera 4 on 4
th
address (ON, ON, OFF, OFF, OFF, OFF)
Etc.
Last camera: Jumper K4 on PCB OFF
The information in this manual is subject to change without prior notice.