Velleman EVM892 User Manual
Page 13

EVM892
29.04.2010
©Velleman
nv
13
DC Voltage (V )
Range Resolution
Accuracy
200mV 100µV
± 0.8% of rdg ± 2 digits
2V 1mV
20V 10mV
200V 100mV
600V 1V
± 1.0% of rdg ± 2 digits
Input Impedance: 10MΩ for all ranges
AC Voltage (V
)
Range Resolution
Accuracy
20V 10mV
± 0.8% of rdg ± 3 digits
200V 100mV
600V 1V
± 1.2% of rdg ± 3 digits
Input Impedance: 10MΩ for all ranges
Frequency Range: 40 to 400Hz
DC Current (A )
Range Resolution
Accuracy
20mA 10µA
± 1.2% of rdg ± 2 digits
200mA 100µA ± 1.5% of rdg ± 1 digit
10A 10mA
± 2.0% of rdg ± 5 digits
Overload Protection: 0.2A/250V resettable fuse, 10A/250V fuse for 10A range
Max. Input Current: 10A (max.10 seconds every 15 minutes)
AC Current (A
)
Range Resolution
Accuracy
20mA 10µA ± 1.2% of rdg ± 2 digits
200mA 100µA ± 1.8% of rdg ± 2 digits
10A 10mA
± 3.0% of rdg ± 7 digits
Overload Protection: 0.2A/250V resettable fuse, 10A/250V fuse for 10A range
Frequency Range: 40 to 400Hz
Max. Input Current: 10A (max.10 seconds every 15 minutes)
Frequency Range: 40 to 400Hz
Resistance
Range Resolution
Accuracy
200Ω 0.1Ω
± 0.8% of rdg ± 3 digits
2kΩ
1Ω
± 0.8% of rdg ± 2 digits
20kΩ 10Ω
200kΩ 100Ω
2MΩ 1kΩ
20MΩ 10kΩ
± 1.8% of rdg ± 2 digits
Capacitance
Range Resolution
Accuracy
200nF 100pF
± 4% of rdg ± 5 digits
2µF 1nF
20µF 10nF