SOL30UC12V & SOL30UC24V
Rev. 04
25/11/2010 4 ©Velleman
nv
4. Overview
Refer to the drawings on page 2 of this manual.
1 LCD
4 Cover
7 Connections for solar panel
2 Display switch
5 Metal mounting plate 8 Connections for battery
3 Load on/off switch
6 Mounting holes (4x)
9 Connections for DC load
set-up c
DC/AC convertor*
* not included
a solar panel
*
d DC load
*
b battery
*
e AC load
*
5.
Installation
• Mount the regulator in a cool and ventilated, but dry location using the 4 mounting
holes [6]. Use M4x20 screws (not included) for easy mounting.
• First connect a 12V (SOL30UC12V) rechargeable battery [b] (not incl.) or a 24V
(SOL30UC24V) rechargeable battery [b] (not included) to connections [8]. Use the
correct polarity!
Note: use multi-core insulated copper wire of at least 6mm² and strip ±5mm.
• Then connect a solar panel [a] (not incl.) to connections [11]. Make sure the
connected solar panel is in accordance with the specifications of this regulator. Use the
correct polarity!
• Finally connect a DC device or appliance [d] (not included) to connections [9]. Make
sure the connected load is in accordance with the specifications of this regulator and
switched off. Use the correct polarity!
• When connecting an AC load [e] (not incl.), install a suitable DC-to-AC convertor [c]
(not incl.) between battery [b] and load [e].
Do not short circuit or reverse polarity of battery, solar panel or load, as
this will lead to irreversible damage.
• To disconnect the regulator, first disconnect the solar panel [a], then the load [d or e]
and finally the battery [b].
• Note that shorter connection wires will reduce power losses.
6.
Protection modes
• Over-discharge protection mode. This mode will be enabled when the battery
voltage becomes too low. The power to the output connectors [9] is cut off to prevent
damage to the battery. Remove the load from the connector and wait until the battery
is fully recharged.
• Over-charge protection mode. This mode will be enabled when the battery voltage
becomes too high. The power from the solar panel input connector [7] is cut off to
prevent damage to the battery until the voltage drops below an acceptable level.
• Over-load protection mode. This mode will be enabled when the load draws a
current of more than 30A.
• Load short circuit protection mode. Enabled when a short circuit in the load is
detected.
• Reverse polarity protection: in order to prevent possible damage the regulator will
not function when reversed connecting polarity is detected. Correct the polarity to use
the regulator.
7.
Use
• LCD [1] can show either battery voltage (A), discharge (output) current from battery
to load (B) or charging current from solar panel to battery (C). Use switch [2] to
scroll through the display modes, refer to the icons on top to know what is being
displayed.