Cleaning, Technical specification – Velleman VTBAL22 User Manual
Page 4

VTBAL22
10/01/2011
4
©Velleman
nv
•
Place the indicated standard calibration weight onto the weighing
platform.
•
Wait a couple of seconds until “PASS” is displayed. The scales are
now calibrated and ready for use.
c. Other Functions
•
Press the CAL / MODE button to choose the weighing unit: g
(grams), oz (ounces), ozt (troy ounces), dwt (pennyweight), ct
(carats), grain and tl (tael).
•
“LO‐ ‐”: low battery indication. Replace the batteries with of the
same type and specifications.
•
“O‐ ‐Ld”: weight overload.
6. Cleaning
•
Do not use abrasive solutions or solvents e.g. benzene. Only use
clean water.
•
Do not submerge the scale in water or any other liquid.
7. Technical Specification
capacity
500g
resolution
0.1g
tare range
0‐500g
operating temperature
15°C ~ 35°C
power supply
2 x 1.5V AAA batteries LR03C (incl.)
dimensions
100 x 80 x 19 mm
Use this device with original accessories only. Velleman nv cannot be
held responsible in the event of damage or injury resulted from
(incorrect) use of this device. For more info concerning this product
and the latest version of this user manual, please visit our website
www.velleman.eu. The information in this manual is subject to
change without prior notice.