High alarm settings, Low alarm settings, 5 minimum and maximum – Velleman WS1060 User Manual
Page 9: Displaying minimum and maximum measurements

WS1060
V. 02 – 26/04/2013
9
©Velleman nv
5. Press ALARM to enable/disable the alarm. If the alarm is enabled, the corresponding alarm indicator
and
HI AL (or LO AL for a low alarm) appear on the display.
6. Press SET to confirm the current setting and go to the next. 
7. To return to normal mode, press HISTORY. 
High alarm settings 
High alarm 
Description
Time alarm
Set the time (hours:minutes) when you want the alarm to go off. 
Note: you can also set the time alarm via low alarms settings. 
Wind speed
Set the wind speed threshold value (0~50m/s). The alarm goes off when the wind speed 
is higher than the specified value. 
Gust speed
Set the gust speed threshold value (0~50m/s). The alarm goes off when the gust speed 
is higher than the specified value. 
Wind direction
Set the wind direction. The alarm goes off when the wind comes from the specified 
direction. 
1 hour rainfall
Set the value of rainfall in 1 hour (0~999.9mm). The alarm goes off when there is more 
rain in 1 hour than the specified value. 
24 hour rainfall
Set the value of rainfall in 24 hours (0~999.9mm). The alarm goes off when there is 
more rain in 24 hours than the specified value. 
Outdoor humidity
Set the outdoor humidity value (1%~99%). The alarm goes off when the outdoor 
humidity is higher than the specified value. 
Outdoor 
temperature 
Set the outdoor temperature value (-40°C~+60°C). The alarm goes off when the 
outdoor temperature is higher than the specified value. 
Wind chill
Set the wind chill value (-40°C~+60°C). The alarm goes off when the wind chill 
temperature is higher than the specified value. 
Dew point
Set the dew point value (-40°C~+60°C). The alarm goes off when the dew point 
temperature is higher than the specified value. 
Indoor humidity
Set the indoor humidity value (1%~99%). The alarm goes off when the indoor humidity 
is higher than the specified value. 
Indoor temperature
Set the indoor temperature value (-9.9°C~+60°C). The alarm goes off when the indoor 
temperature is higher than the specified value. 
Low alarm settings 
Low alarm 
Description
Outdoor humidity
Set the outdoor humidity value (1%~99%). The alarm goes off when the outdoor 
humidity is lower than the specified value. 
Outdoor 
temperature 
Set the outdoor temperature value (-40°C~+60°C). The alarm goes off when the 
outdoor temperature is lower than the specified value. 
Wind chill
Set the wind chill value (-40°C~+60°C). The alarm goes off when the wind chill 
temperature is lower than the specified value. 
Dew point
Set the dew point value (-40°C~+60°C). The alarm goes off when the dew point 
temperature is lower than the specified value. 
Indoor humidity
Set the indoor humidity value (1%~99%). The alarm goes off when the indoor humidity 
is lower than the specified value. 
Indoor temperature
Set the indoor temperature value (-9.9C~+60°C). The alarm goes off when the indoor 
temperature is lower than the specified value. 
7.5
Minimum and maximum
The weather station keeps track of minimum and maximum measurements for each weather condition (since 
the last reset), together with the time and date when they were recorded. 
Displaying minimum and maximum measurements 
To display minimum and maximum measurements, proceed as follows: 
1. From normal mode, press MIN/MAX. 
The station is now in maximum mode. The displays shows the maximum indicator [6].
2. Press + repeatedly to display the maximum values for: wind speed, gust speed, 1 hour rainfall, 24 hour
rainfall, weekly rainfall, monthly rainfall, outdoor humidity, outdoor temperature, wind chill temperature, 
dew point, indoor humidity, indoor temperature. 
3. Press MIN/MAX to go to minimum mode. The displays shows the minimum indicator [8].
