Velleman UPS600N1 User Manual
Page 6
UPS600N1
00 (26/11/2008)
6
Velleman
®
10.
Troubleshooting
problem possible
cause
solution
no light, no alarm
power switch off
press the power switch [A]
loose power cord
plug power cord firmly in wall socket
circuit breaker active
check load on UPS and press the circuit
breaker [G]
backup time less
than rating
battery not fully charged
recharge battery for at least 6 hours
battery end of life
replace battery
charger defective
contact your local dealer
11.
Battery
• To replace the battery, switch the UPS off and unplug all the power cords (mains and
connected devices).
• Remove the top cover of the UPS by releasing the four screws.
• Disconnect the terminals. Be extremely careful not to touch any other terminals or wires
inside the housing.
• Remove the battery from the housing and replace it with and identical type of battery (use a
WPE7.2-12).
• Connect the terminals following the right polarity.
• Re-install the top cover and secure it with the 4 screws.
Dispose of batteries in accordance with local regulations.
Do not try to open the battery housing.
Do not throw batteries in fire as they may explode.
Keep batteries away from children.
12.
Technical specifications
input voltage
230Vac +/- 25%
input frequency
50Hz
back-up time
1.5 ~ 15 minutes depending on connected load
connections
4x IEC-320 C13 (CEE 22) outlets
2x RJ-45 modular sockets for telephone line/network
protection
1x USB connector for software communication with PC
optional power cables (not incl.) NET3B (1.8m), NET3B3M (3m)
beeping alarm
in case of battery on, low battery and overload
spare battery
WPE7.2-12
power capacity
600VA
weight 7.5kg
dimensions
325 x 120 x 140mm
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use of this
device.
For more info concerning this product, please visit our website
www.velleman.eu
.
The information in this manual is subject to change without prior notice.