Velleman VDPSP151 User Manual
Page 2
VDPSP151 2 VELLEMAN
The 4 SHUCKO output sockets each allow a maximum load of 1100W (5A).
Remark: Never surpass the maximum total current of 16A!
For each channel, there is a LED to show the actual status of the channel.
5. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, controls and connectors should not be deformed or modified.
3. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
4. Disconnect the device from the mains prior to maintenance activities.
5. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
6. There are no user-serviceable parts, apart from the fuse. When a fuse blows: switch the device off, unscrew the
fuse holder of the blown fuse with an appropriate screwdriver (see figure above), replace the fuse by a fuse of the
same type and specifications, and screw the fuse holder back on.
7. Contact your dealer for spare parts if necessary.
6. Technical Specifications
Power Supply
max. 230VAC/50Hz
Number of Channels
4
Maximum Total Load
3520W
Maximum Total Current
16A
Maximum Load per Channel
1100W
Output Connections
4 x SHUCKO socket
Analogue Input
8-pin DIN socket (0-10V DC)
Analogue Output
8-pin DIN socket (0-10V DC)
Fuses
4 x F 6.3A, 250VAC (5 x 20mm) (order code FF6.3N)
circuit breaker 16A
Dimensions
298 x 165 x 96mm
Total Weight
2.8kg
The information in this manual is subject to change without prior notice.