beautypg.com

Velleman VDPL300MF4 User Manual

Page 6

background image

VDPL300MF4_v3

HQPOWER™

6

7

LED cluster 6

0 31

No

mode

32

63

Auto mode 1

64

95

Auto mode 2

96

127

Auto mode 3

128 131

No

mode

132 255

Static

colour

8

LED cluster 7

0 31

No

mode

32

63

Auto mode 1

64

95

Auto mode 2

96

127

Auto mode 3

128 131

No

mode

132 255

Static

colour

9 Strobe

0 9

No

strobe

10

209

Fast to slow

210 255

Sound

activation


DMX512 Connection

Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-
pin XLR input of the VDPL300MF4. Multiple VDPL300MF4s can be linked through serial linking. The linking cable

should be a two-core screened cable with XLR input and output connectors.

DMX512 Chain with Termination

A DMX terminator is recommended for installations where the DMX cable has to run a

long distance or is in an electrically noisy environment (e.g. discos). The terminator
prevents corruption of the digital control signal by electrical noise. The DMX terminator is

simply an XLR plug with a 120Ω resistor between pins 2 and 3, which is then plugged into
the XLR output socket of the last device in the chain.

Please see illustrations.

DMX512 Start Address


All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This start

address is the channel number from which the device starts to “listen” to the DMX controller. Enter the correct
number and read it from the display located on the base of the VDPL300MF4.

You can use the same starting address for a whole group of devices or enter an individual one for every device.
When all devices have the same address, all the VDPL300MF4s will “listen” to the control signal on one particular

channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you set
different addresses, each device will “listen” to a separate channel number. Changing the settings of one channel will

only affect the device in question.
In the case of the 9-channel VDPL300MF4, you will have to set the start address of the first VDPL300MF4 to 1, the

second VDPL300MF4 to 10 (1 + 9), the third to 19 (10 + 9) and so on.

8. Cleaning and Maintenance


1. All screws should be tightened and free of corrosion.

2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)

should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not

change the location of the connections.

3. Moving mechanic parts must not show any signs of wear and tear.

4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.