Replacing the lamp, Cleaning and maintenance, Technical specifications – Velleman VTLAMP8 User Manual
Page 4
VTLAMP8
V. 02 – 30/04/2013
4
©Velleman nv
5.
Replacing the Lamp
Refer to the illustration on page 2 of this manual.
1. Unplug the device and let the circular fluorescent lamp cool down before replacing it.
2. The lamp is located behind a plastic diffuser.
Gently bend the stem so that the diffuser points upwards.
3. Remove the 5 screws [x] holding the plastic diffuser in place. Remove the diffuser carefully and
make sure not to drop the lamp.
4. Hold the lamp at the plastic ring and disconnect the lamp from the connector. Pull on the connector,
not the cables. Take out the defective lamp.
5. Install a new lamp (order code LAMP22/8) and insert the connector.
6. Put the diffuser back and fasten the screws.
Caution: If the plastic diffuser is damaged, disconnect the lamp immediately from the mains. The
diffuser is not replaceable. Do not use the lamp with a cracked or broken diffuser.
6.
Cleaning and Maintenance
Unplug the device from the mains and let the lamp cool down before maintenance.
Wipe the device with a moist soft cloth. Do not use abrasives or solvents.
7.
Technical Specifications
dioptre
3 + 12 (x1.75 + x4)
dimensions
arm length
25 cm
width
14 cm
height
36 cm
colour
white
power supply
230 Vac / 50-60 Hz
cable length
1.2 m
spare lamp
order code LAMP22/8
spare magnifying glass cover
order code VTLAMP8/SP1
ideal ambient temperature
0 °C – 35 °C
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulting from (incorrect) use of this device.
For more info concerning this product and the latest version of this manual, please visit our
website www.velleman.eu.
The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part
of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise
without the prior written consent of the copyright holder.