beautypg.com

4 mounting - sensor housing – VEGA VEGAFLEX series 80 - External housing User Manual

Page 8

background image

8

4 Mounting

External housing • VEGAFLEX 80 series

46802-EN-131120

Tip:

Mount the wall mounting plate in such a way that the cable gland of

the base points downward. Rain and condensation water can thus

drain off.
The base of stainless steel can be displaced in 90° increments on the

wall mounting plate, the base of plastic by 180°.
Turn the cable gland of the electronics housing downward. The hous-

ing can be turned by 330° without the use of any tools.

Warning:

With the plastic housing, the four screws of the base may only be

screwed in hand tight. Exceeding the max. torque specified in chapter

"Technical data" can damage the wall mounting plate.

4.4 Mounting - sensor housing

Mount the sensor to the bottom, depending on the process fitting

Note:

When mounting the sensor, note the instructions in the operating

instructions manual of the sensor.