VEGA VEGABAR 83 Save sensor - Operating Instructions User Manual
Page 45
45
9 Supplement
VEGABAR 83 • Slave sensor for electronic differential pressure
45051-EN-131011
Nominal range
Overload capacity, max.
pressure
Overload capacity, min. pres-
sure
-14.5 … +1500 psig
(only for measuring cell ø 28 mm)
+2900 psig
-14.51 psig
-0.7 … +0.7 psig
+225 psig
-2.901 psig
-3 … +3 psig
+290 psi
-5.800 psig
-7 … +7 psig
+510 psig
-14.51 psig
Absolute pressure
0 … 1.5 psi
225 psig
0 psi
0 … 5 psi
435 psi
0 psi
0 … 15 psi
510 psi
0 psi
0 … 30 psi
725 psi
0 psi
0 … 150 psi
1300 psi
0 psi
0 … 300 psi
1900 psi
0 psi
0 … 900 psi
2900 psi
0 psi
0 … +1450 psig
(only for measuring cell ø 28 mm)
2900 psig
0 psi
Reference conditions and actuating variables (according to DIN EN 60770-1)
Reference conditions according to DIN EN 61298-1
Ʋ Temperature
+18 … +30 °C (+64 … +86 °F)
Ʋ Relative humidity
45 … 75 %
Ʋ Air pressure
860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psi)
Determination of characteristics
Limit point adjustment according to IEC 61298-2
Characterstic curve
Linear
Reference installation position
upright, diaphragm points downward
Influence of the installation position
Ʋ Piezoresistive/strain gauge measur-
ing cell
depending on the process fitting and the chemical seal
Ʋ METEC
®
measuring cell
< 5 mbar/0.5 kPa (0.07 psig)
Deviation (according to IEC 60770)
Specifications refer to the set span. Turn down (TD) is the ratio: nominal measuring range/set span.
Accuracy class
Non-linearity, hysteresis and re-
peatability with TD 1 : 1 up to 5 : 1
Non-linearity, hysteresis and re-
peatability with 5 : 1
0.075 %
< 0.075 %
< 0.015 % x TD
0.1 %
< 0.1 %
< 0.02 % x TD
0.2 %
< 0.2 %
< 0.04 % x TD
Influence of the product or ambient temperature
Thermal change zero signal and output span
Turn down (TD) is the relation nominal measuring range/adjusted span.