beautypg.com

VEGA VEGABAR 83 Save sensor - Operating Instructions User Manual

Page 45

background image

45

9 Supplement

VEGABAR 83 • Slave sensor for electronic differential pressure

45051-EN-131011

Nominal range

Overload capacity, max.

pressure

Overload capacity, min. pres-

sure

-14.5 … +1500 psig
(only for measuring cell ø 28 mm)

+2900 psig

-14.51 psig

-0.7 … +0.7 psig

+225 psig

-2.901 psig

-3 … +3 psig

+290 psi

-5.800 psig

-7 … +7 psig

+510 psig

-14.51 psig

Absolute pressure
0 … 1.5 psi

225 psig

0 psi

0 … 5 psi

435 psi

0 psi

0 … 15 psi

510 psi

0 psi

0 … 30 psi

725 psi

0 psi

0 … 150 psi

1300 psi

0 psi

0 … 300 psi

1900 psi

0 psi

0 … 900 psi

2900 psi

0 psi

0 … +1450 psig
(only for measuring cell ø 28 mm)

2900 psig

0 psi

Reference conditions and actuating variables (according to DIN EN 60770-1)
Reference conditions according to DIN EN 61298-1

Ʋ Temperature

+18 … +30 °C (+64 … +86 °F)

Ʋ Relative humidity

45 … 75 %

Ʋ Air pressure

860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psi)

Determination of characteristics

Limit point adjustment according to IEC 61298-2

Characterstic curve

Linear

Reference installation position

upright, diaphragm points downward

Influence of the installation position

Ʋ Piezoresistive/strain gauge measur-

ing cell

depending on the process fitting and the chemical seal

Ʋ METEC

®

measuring cell

< 5 mbar/0.5 kPa (0.07 psig)

Deviation (according to IEC 60770)
Specifications refer to the set span. Turn down (TD) is the ratio: nominal measuring range/set span.

Accuracy class

Non-linearity, hysteresis and re-

peatability with TD 1 : 1 up to 5 : 1

Non-linearity, hysteresis and re-

peatability with 5 : 1

0.075 %

< 0.075 %

< 0.015 % x TD

0.1 %

< 0.1 %

< 0.02 % x TD

0.2 %

< 0.2 %

< 0.04 % x TD

Influence of the product or ambient temperature
Thermal change zero signal and output span
Turn down (TD) is the relation nominal measuring range/adjusted span.