beautypg.com

VEGA VEGAPULS 68 (≥ 2.0.0 - ≥ 4.0.0) HART - integrated accumulator User Manual

Page 3

background image

3

Quick start

VEGAPULS 68 • HART - integrated accumulator

40935-EN-121011

3. Select in the menu item "Application" the vessel, the application

and the vessel form, for example, silo.

4. Carry out the adjustment in the menu items "Min. adjustment" and

"Max. adjustment".

The radar sensor as a distance measuring instrument measures the

distance from the sensor to the product surface. For indication of the

real level, an allocation of the measured distance to the percentage

height must be carried out.

2

1

100%

0%

1 m

(39.37

")

35 m (1378

")

Fig. 3: Parameterization example
1 Min. level
max. meas. distance

2 Max. level min. meas. distance

For this adjustment, the distance is entered for min. and max. level.

If these values are not known, an adjustment with distances, for

example, of 10 % and 90 % is also possible. Starting point for these

distance specifications is always the seal surface of the thread or

flange.
1. In the menu "Additional settings", menu item "Damping" you have

to adjust the requested damping of the output signal.

2. Select the output characteristics in the menu item "Current out-

put".

The quick start is then finished. For further information see chapter

"Parameter adjustment".

Parameterization example

Further steps