beautypg.com

2 mounting instructions – VEGA VEGASWING 66 - transistor (NPN-PNP) With SIL qualification User Manual

Page 13

background image

13

4 Mounting

VEGASWING 66 • - transistor (NPN/PNP)

44951-EN-130805

weight of the instrument. Transport coated instruments very carefully

and avoid touching the tuning fork.
Remove the packaging or the protective cover just before installation.

The vibrating level switch is a measuring instrument and must be

treated accordingly. Bending the vibrating element will destroy the

instrument.

Warning:

The housing must not be used to screw the instrument in! Applying

tightening force can damage internal parts of the housing.
Use the hexagon above the thread for screwing in.

4.2 Mounting instructions

The thread and the seal on the threaded version of VEGASWING 66

correspond to DIN 3852 part 1, screwed plug Form B (sealing via

metallic sealing edge).
Use screw-in openings or screw-in sleeves according to DIN 3852

part 2.
For mounting, proceed as follows:
1. Screw the VEGASWING 66 into the mounting boss up to the stop.

You can determine the later position already before welding.

2. Mark the position of the VEGASWING 66 on the mounting boss.
3. Mark the respective position of the mounting boss on the vessel

or pipeline.
In case of lateral mounting, make sure the mark on the spanner

flat of VEGASWING 66 points upwards.
When mounting in pipelines, make sure that the surfaces of the

tuning fork are parallel to the direction of flow.

4. Remove the VEGASWING 66 from the mounting boss before

welding.

5. Weld the mounting boss according to your marking.

In case of horizontal mounting in adhesive and viscous products,

the surfaces of the tuning fork should be vertical in order to reduce

buildup on the tuning fork. On the screwed version you will find a

marking on the hexagon. With this, you can check the position of the

tuning fork when screwing it in.
In the case of flange versions, the fork is aligned with the flange holes.
When used in adhesive and viscous products, the tuning fork should

protrude into the vessel to avoid buildup. For that reason, sockets

for flanges and mounting bosses should be avoided when mounting

horizontally.

The process fitting must be sealed if there is gauge or low pressure in

the vessel. Before use, check if the seal material is resistant against

the measured product and the process temperature.

Handling

Welded socket

Adhesive products

Pressure/Vacuum