beautypg.com

2 principle of operation – VEGA VEGABAR 87 Save sensor - Operating Instructions User Manual

Page 8

background image

8

3 Product description

VEGABAR 87 • Slave sensor for electronic differential pressure

45053-EN-131011

This operating instructions manual applies to the following instrument

versions:

Hardware from 1.0.0

Software version from 1.0.0

The scope of delivery encompasses:

VEGABAR 87 pressure transmitter

Connection cable to the master sensor

Cable gland for the master sensor

Documentation

– this operating instructions manual

– Test certificate measuring accuracy (optional)

– Supplementary instructions manual "Plug connector for con-

tinuously measuring sensors" (optional)

– Ex-specific "Safety instructions" (with Ex versions)

– if necessary, further certificates

3.2 Principle of operation

The VEGABAR 87 slave sensor is combined with a sensor from the

VEGABAR 80 series for electronic differential pressure measurement.
The sensors are connected via a screened four-wire cable. The

measured value from the slave sensor is read in and factored into the

calculations. Parameter adjustment is carried out through the master

sensor.

The differential pressure measurement is suitable for the measure-

ment of the following process variables:

Level

Flow

Differential pressure

Density

Interface

Scope of this operating

instructions manual

Scope of delivery

Electronic differential

pressure measurement

Measured variables