beautypg.com

4 mounting in a standpipe, 1 mounting - cable version – VEGA VEGAFLEX 81 Ship-building User Manual

Page 17

background image

17

4 Mounting in a standpipe

VEGAFLEX 81 • Cargo tank (crude oil)

39154-EN-130626

4 Mounting in a standpipe

4.1 Mounting - cable version

In narrow tanks or in case of a distance to vessel installations of less

than 300 mm (11.81 in), measurement in a standpipe is recom-

mended.

1

2

3

Fig. 27: Measurement in a standpipe
1 The sensor cable must not touch the vessel wall

2 Standpipe mounting with gravity weight and spring

3 Standpipe mounting with gravity weight and centering disk

The sensor cable must be tightly stretched with a gravity weight or

spring. The measurement will not function if the sensor cable touches

the inner wall of the standpipe.