36524-EN-121011

Ʋ Inspection window

Polyester foil

Integrated clock
Date format

Day.Month.Year

Time format

12 h/24 h

Time zone Ex factory

CET

Measurement electronics temerature
Resolution

1 °C (1.8 °F)

Accuracy

±1 °C (1.8 °F)

Voltage supply
Operating voltage

Ʋ Version for low voltage

9.6 … 48 V DC, 20 … 42 V AC, 50/60 Hz

Ʋ Version for mains voltage

90 … 253 V AC, 50/60 Hz

Interpolation protection

Integrated

Max. power consumption

4 VA; 2.1 W

Electrical protective measures
Protection rating

IP 66/IP 67

Overvoltage category

III

Protection class

I

Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments must be carefully noted.

They are part of the delivery or can be downloaded under www.vega.com and "VEGA Tools" as

well as under "Downloads" and "Approvals".

11.2 Dimensions

The following dimensional drawings represent only an extract of all possible versions. Detailed

dimensional drawings can be downloaded at www.vega.com/downloads under "Drawings".

Housing

1

~ 87 mm (3.43")

M16x1,5

ø 84 mm

(3.31")

120 mm (4.72"

)

M20x1,5/

½ NPT

Fig. 17: Dimensions housing - with integrated indicating and adjustment module the housing is 9 mm/0.35 in

higher