beautypg.com

VEGA VEGAMIP R61 Receiving unit - Relay User Manual

Page 19

background image

2

1

2

2

1

1

Fig. 10: Front flush installation

1

Plastic or ceramic material

2

Fixing screw (if technically possible)

In very abrasive products, VEGAMIP 61 should be installed with a
mounting adapter or in front of a suitable window. In this case, you
have to use a window material which is appropriately resistant.

In case of strong vessel vibrations, the VEGAMIP 61 should be
mounted with anti vibration blocks or rubber buffers.

Abrasive medium

Vibrations

VEGAMIP R

61 • - Relay

19

4 Mounting

35786

-

EN

-120228