VEGA VEGAPULS 68 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - four-wire User Manual
Page 69
69
11 Supplement
VEGAPULS 68 • 4 … 20 mA/HART - four-wire
36536-EN-121011
Reflux valve - unmounted (as option with non-Ex version, included in the scope of delivery with Ex
version)
Ʋ Material
316Ti
Ʋ Seal
FKM (Viton), FFKM (Kalrez 6375)
Ʋ for tube diameter
6 mm
Ʋ opening pressure
0.5 bar (7.25 psig)
Ʋ Nominal pressure stage
PN 250
Electromechanical data - version IP 66/IP 67
Options of the cable entry
Ʋ Cable gland
M20 x 1.5 (cable: ø 5 … 9 mm)
Ʋ Cable entry
½ NPT
Ʋ Blind stopper
M20 x 1.5; ½ NPT
Ʋ Closing cap
M20 x 1.5; ½ NPT
Plug options
Ʋ Supply and signal circuit (only with low
voltage)
M12 x 1
Ʋ Indication circuit
M12 x 1
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, cord
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Indicating and adjustment module
Voltage supply and data transmission
through the sensor
Indication
LC display in dot matrix
Measured value indication
Ʋ Number of digits
5
Ʋ Size of digits
W x H = 7 x 13 mm
Adjustment elements
4 keys
Protection rating
Ʋ unassembled
IP 20
Ʋ mounted into the sensor without cover IP 40
Materials
Ʋ Housing
ABS
Ʋ Inspection window
Polyester foil
Integrated clock
Date format
Day.Month.Year
Time format
12 h/24 h
Time zone Ex factory
CET
Measurement electronics temerature
Resolution