6 Set up

6.1 General

The numbers in brackets refer to the following illustrations.

On the electronics module you will find the following indicating

and adjustment elements:

l

Potentiometer for switching point adaptation (1)

l

DIL switch for mode adjustment - min./max. (2)

l

Simulation key (3)

l

Signal lamp (6)

6.2 Adjustment elements

Simulation

NAMUR IEC 60947-5-6

VB60N

4

5

6

1

2

3

Fig. 14: Oscillator VB60N - NAMUR output

1

Potentiometer for switching point adaptation

2

DIL switch for characteristics reversal

3

Simulation key

4

Ground terminal

5

Screwed terminals

6

Control lamp

You can adapt the switching point to the solid with the

potentiometer. The switching point is preset and covered by a

label. It must only be modified in special cases.
By default, the potentiometer of VEGAVIB 67 is set to

complete right position (>0.02 g/cm³ or >0.0008 lbs/in³). In

Function/Configuration

Switching point adaptation (1)