VEGA VEGAFLEX 63 4 … 20 mA_HART two-wire User Manual
Page 51
Influence of the ambient temperature to the sensor electronics
T
emperature drift
0.03 %/10 K
relating to the max. measuring range
or max. 0.3 %
T
emperature drift - Digital output
3
mm/10 K relating to the max. measuring range or
max. 10 mm
Ambient conditions
A
mbient, storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
P
rocess pressure
-
F
lange version ≤ 2"/DN 50
-0.5 … +16
bar/-50 … +1600 kPa (-7.3 … +232 psig),
depending on the process fitting
-
F
lange version > 2"/DN 50
-0.2 … +16
bar/-20 … +1600 kPa (-2.9 … +232 psig),
depending on the process fitting
P
rocess temperature (flange temperature)
-40 … +150 °C (-40 … +302 °F)
T
he measurement error from the process condi-
tions is in the specified pressure and temperature
range of below 1 %.
0 °C
(32 °F)
40 °C
(104 °F)
20 °C
(58 °F)
60 °C
(140 °F)
80 °C
(176 °F)
50 °C
(122 °F)
-40 °C
(-40 °F)
100 °C
(212 °F)
150 °C
(302 °F)
1
2
Fig. 29: Ambient temperature - Process temperature
1
Ambient temperature
2
Process temperature (depending on the seal material)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
C
able entry/plug
3)
-
S
ingle chamber housing
l
1
x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1
x blind stopper M20 x 1.5
or:
l
1
x closing cap M20 x 1.5; 1 x blind stopper
M
20
x 1.5
3)
D
epending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.
VEGAFLEX
63 • 4 … 20
mA/HART two-wire
51
10 S
upplement
31841
-
EN
-100426