VEGA Bypass 72 Bypass tube with VEGAFLEX level sensor User Manual
Page 5

1
2
B
A
4
(1,056)
3
(0,793)
2
(0,528)
1
(0,264)
5
(1,321)
6
(1,585)
7
(1,849)
8
(2,113)
2500
(98
7
/
16
")
3000
(118
1
/
8
")
2000
(78
3
/
4
")
1500
(59
1
/
16
")
500
(19
5
/
8
")
1000
(39
3
/
8
")
0%
100%
0
Fig. 2: Volume of the bypass tube
1
Tube length in mm (in)
2
Volume in L (US.liq.gal)
A
Standard version
B
High pressure version
Process temperature
see process fitting - connection flange (B,C)
Process pressure
see process fitting - connection flange (B,C)
Process fitting - Measuring instrument flange (A)
DN 50 PN 40, Form C, DIN 2501
Flange 2" 300 lb RF, ANSI B16.5
Process fitting - connection flange top/bottom (B, C)
Process pressure in bar (psig) depending on the process temperature
Process temperature 150 °C (302 °F)
Flanges
Process pressure
Seal
Wall thickness
Flange DN 20 PN 40, Form C,
DIN 2501
12 bar (174 psig)/31 bar (450 psig) Klingersil
2 mm (0.079 in)
Flange DN 25 PN 40, Form C,
DIN 2501
12 bar (174 psig)/31 bar (450 psig) Klingersil
2 mm (0.079 in)
Flange DN 50 PN 40, Form C,
DIN 2501
12 bar (174 psig)/31 bar (450 psig) Klingersil
2 mm (0.079 in)
Bypass 72 • with VEGAFLEX level sensor
5
3 Supplement
33545
-
EN
-081216
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)