9 supplement, 1 technical data – VEGA VEGACAL External housing User Manual
Page 15

15
9 Supplement
External housing • VEGACAP, VEGACAL
31085-EN-130916
9 Supplement
9.1 Technical data
Technical data
Following you find all data deviating from the standard instrument. All other technical data are
specified in the operating instruction of the respective sensor.
General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, non-wetted parts
Ʋ Sensor housing - metal housing IP 68
(10 bar)
316L
Ʋ Sensor housing - metal housing IP 67 316L
Ʋ Sensor housing - BNC plug IP 54
316L
Ʋ External housing (instrument housing) plastic PBT (Polyester)
Ʋ Housing socket
plastic PBT (Polyester)
Ʋ Wall mounting plate
plastic PBT (Polyester)
Ʋ Seal between housing socket and wall
mounting plate
TPE (fixed connected)
Ʋ Seal between housing and housing
cover (instrument version)
Silicone
Ʋ Ground terminal
316L
Ʋ Connection cable
FEP
Weights
Ʋ External plastic housing
660 g (23 oz)
Ʋ Sensor housing - IP 68 (10 bar)
1100 g (38 oz)
Ʋ Sensor housing - IP 67
400 g (14.1 oz)
Ʋ Sensor housing - IP 54
190 g (6.7 oz)
Process fittings
Ʋ Sensor housing - IP 68 (10 bar)
G¾, ¾ NPT, G1, 1 NPT, G1½, 1½ NPT
Ʋ Sensor housing - IP 67
G½, ½ NPT
Ʋ Sensor housing - IP 54
G½, ½ NPT
Cable length to the external housing
2 … 10 m (6.562 … 32.81 ft)
Process conditions
Process pressure
-1 … 63 bar/-100 … 6400 kPa (-14.5 … 928 psig)
Process temperature
Depending on the sensor
Ambient temperature on the sensor
housing
-50 … +150 °C (-58 … +302 °F)
Ambient temperature on the sensor
housing - with BNC plug connection
-50 … +100 °C (-58 … +212 °F)
Ambient temperature on the connection
cable
-50 … +150 °C (-58 … +302 °F)
Ambient, storage and transport temperature on the instrument housing