Product density
-
Standard
>
0.02 g/cm³ (0.0007 lbs/in³)
-
adjustable
>
0.008 g/cm³ (0.0003 lbs/in³)
Granular size
max. 10 mm (0.4 in)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
3)
-
Single chamber housing
l
1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5
Spring-loaded terminals
for wire cross-section up to 1.5 mm² (AWG 16)
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
-
Single chamber housing
l
1 x IP 68 cable gland M20 x 1.5; 1 x blind
stopper M20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
Connection cable
-
Wire cross-section
0.5 mm² (AWG 20)
-
Wire resistance
<
0.036 Ω/m (0.011 Ω/ft)
-
Tensile strength
<
1200 N (270 lbf)
-
Standard length
5 m (16.4 ft)
-
Max. length
1000 m (3280 ft)
-
Min. bending radius
25 mm (0.984 in) with 25 °C (77 °F)
-
Diameter approx.
8 mm (0.315 in)
-
Colour - standard PE
Black
-
Colour - standard PUR
Blue
-
Colour - Ex-version
Blue
Adjustment elements
Mode switch
-
Min.
Min. detection or dry run protection
-
Max.
Max. detection or overflow protection
3)
Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.
VEGAWAVE
61 • - two-wire
33
9 Supplement
32250
-
EN
-120418