VEGA VEGAFLEX 67 (-40…+150°C) 4 … 20 mA_HART two-wire User Manual
Page 49

1
0
m
(3
2
.82
ft
)
1
1
m
(3
6
.09
ft
)
1
2
m
(3
9
.37
ft
)
1
3
m
(4
2
.65
ft
)
1
4
m
(4
5
.93
ft
)
1
5
m
(4
9
.21
ft
)
1
6
m
(5
2
.49
ft
)
1
7
m
(5
5
.77
ft
)
1
8
m
(5
9
.06
ft
)
2
3
m
(7
5
.46
ft
)
1
9
m
(6
2
.34
ft
)
2
4
m
(7
8
.74
ft
)
2
6
m
(8
5
.31
ft
)
2
0
m
(6
5
.62
ft
)
2
1
m
(6
8
.91
ft
)
2
2
m
(7
2
.18
ft
)
2
5
m
(8
2
.02
ft
)
0
1
2
3
4
5
6
7
8
9
10
1
2
Fig. 23: Relation dielectric figure (ε
r
) of the upper medium to the max. probe length
1
Dielectric figure (ε
r
) of the upper medium
2
Max. probe length
Output variable
O
utput signal
4 … 20
mA/HART
C
ycle time
min. 1 s (dependent on the parameter setting)
S
ignal resolution
1.6 µA
F
ailure signal current output (adjustable)
mA-value unchanged 20.5 mA, 22 mA, < 3.6 mA
M
ax. output current
22
mA
L
oad
see load diagram under Power supply
D
amping (63 % of the input variable)
0 … 999
s, adjustable
F
ulfilled NAMUR recommendations
NE
43
HART
output values
-
HART
value (Primary Value)
D
istance to the interface (d1)
-
HART
value (Secondary Value)
H
eight of the interface - scaled (h1)
-
HART
value (3rd Value)
D
istance to the level (d2)
-
HART
value (4th Value)
H
eight of the level - scaled (h2)
VEGAFLEX
67 • 4 … 20
mA/HART - two-wire
49
10 S
upplement
31853
-
EN
-120329
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)