Breaking capacity

-

Min.

50 mW

-

Max.

750 VA AC, 54 W DC
If inductive loads or stronger currents are
switched through, the gold plating on the relay
contact surface will be permanently damaged.
The contact is then no longer suitable for
switching low-level signal circuits.

Contact material (relay contacts)

AgNi or AgSnO and Au plated

Modes (adjustable)

-

A

Max. detection or overfill protection

-

B

Min. detection or dry run protection

Switching delay

approx. 0.5 … 20 s

Ambient conditions

Ambient temperature on the housing

-40 … +70 °C (-40 … +158 °F)

Ambient temperature with operating
voltage >60 V DC

-40 … +50 °C (-40 … +122 °F)

Storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Permissible process temperature

-40 … +100 °C (-40 … +212 °F)

Process pressure

-1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psi)

Conductive of the medium

min. 5 µS/cm with 30 mm electrode covering

Electromechanical data

Cable gland

-

with relay module

1x cable entry M20x1.5; 1x blind stopper
M

20x1.5 (cable gland M20x1.5 is attached)

Screw terminals

for wire cross-section up to 1.5 mm²
(0.0023 in²)

Voltage supply

Supply voltage

20 … 253 V AC, 50/60 Hz, 20 … 72 V DC (at
U >

60 V DC, the ambient temperature can be

max. 50 °C/122 °F)

Power consumption

1 … 9 VA (AC), approx. 1.5 W (DC)

24

VEGAKON

66 - with relay output

Supplement

32649

-EN

-070615