Level

Switching sta-
tus, relay mod-
ule E60R

Control lamp

Mode A
Overflow protec-
tion

1

Relay energized

5

3

4

(8)

(6)

(7)

does not light

Mode A
Overflow protec-
tion

2

Relay deener-

gized

5

3

4

(8)

(6)

(7)

lights

Mode B
Dry run protection

3

Relay energized

5

3

4

(8)

(6)

(7)

does not light

Mode B
Dry run protection

4

Relay deener-

gized

5

3

4

(8)

(6)

(7)

lights

Failure of the
supply voltage
(mode A/B)

Relay deener-

gized

5

3

4

(8)

(6)

(7)

does not light

1

Max. detection - Vessel empty

2

Max. detection - Vessel full

3

Min. detection - Vessel full

4

Min. detection - Vessel empty

Note:
If VEGAKON 66 is used for oil warning in water, the probe
must be cleaned after having responded to oil (= empty signal)
because otherwise resetting to water will not be ensured
reliably.