background image

-

Rod: ø 6 mm (0.236 in)

approx. 220 g/m (2.365 oz/ft)

-

Cable: ø 4 mm (0.157 in)

approx. 80 g/m (0.86 oz/ft)

-

Gravity weight

approx. 325 g (11.5 oz)

Probe length L (from seal surface)

-

Tube: ø 21.3 mm (0.839 in)

up to 6 m (19.69 ft)

-

Trimming accuracy - tube

< 1

mm (0.039 in)

-

Rod: ø 6 mm (0.236 in)

up to 4 m (13.12 ft)

-

Trimming accuracy - rod

< 1

mm (0.039 in)

-

Cable: ø 4 mm (0.157 in)

up to 32 m (105 ft)

-

Trimming accuracy - cable

±0

.05 %

Max. tensile load with cable: ø 4 mm
(0.157 in)

5 KN (1124 lbf)

Lateral load

-

Tube: ø 21.3 mm (0.839 in)

60 Nm (44 lbf ft)

-

Rod: ø 6 mm (0.236 in)

4 Nm (3 lbf ft)

Thread in gravity weight (cable version)

M

12

Input variable

Measured variable

Level of liquids

Min. dielectric figure (lower medium)

by 10 higher than the ε

r

of the upper medium

Min. layer thickness (upper medium)

> 100

mm (3.937 in)

The measured value deviates from the actual level
until the min. layer thickness is reached.

Max. layer thickness (upper medium)

-

Dielectric figure (upper medium) 10

6 m (19.69 ft)

-

Dielectric figure (upper medium) 5

10 m (32.81 in)

-

Dielectric figure (upper medium) 2

20 m (65.61 in)

Min. dielectric figure (upper medium) - coax
version

ε

r

> 1

.4

VEGAFLEX

67 • Foundation Fieldbus

41

10 Supplement

31856

-

EN

-120329