10 supplement, 1 technical data, 10 .1 technical data – VEGA VEGAPULS 67 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART four-wire User Manual
Page 48
10
Supplement
10
.1 Technical data
General data
316L
corresponds to 1.4404 or 1.4435
M
aterials, wetted parts
-
H
orn antenna
PBT-GF30
-
F
ocussing lens
PP
-
A
dapter flange
PPH
-
S
eal, adapter flange
FKM (V
iton)
M
aterials, non-wetted parts
-
H
ousing
A
luminium die-casting powder coated
-
S
eal between housing and housing
cover
NBR (
stainless steel housing), silicone (Alu/plastic
housing)
-
I
nspection window in housing cover for
PLICSCOM
P
olycarbonate (UL-746-C listed)
-
G
round terminal
316T
i/316L
M
ax. torque, mounting screws - strap on the
sensor housing
4 N
m (2.95 lbf ft)
W
eight, depending on housing material and
version
0.7 … 3.4
kg (1.543 … 7.496 lbs)
Output variable
O
utput signal
4 … 20
mA/HART (active)
C
ycle time
min. 1 s (dependent on the parameter setting)
S
ignal resolution
1.6 µA
F
ailure signal current output (adjustable)
mA value unchanged 20.5 mA, 22 mA, < 3.6 mA
(
adjustable)
M
ax. output current
22
mA
L
oad
<
500 Ω
3)
D
amping (63 % of the input variable)
0 … 999
s, adjustable
F
ulfilled NAMUR recommendations
NE
43
HART
output values
-
1. HART
value (Primary Value)
D
istance to the level
-
2. HART
value (Secondary Value)
D
istance to the level - scaled (for example hl, %)
R
esolution, digital
>
1
mm (0.039 in)
Input variable
M
easured variable
3)
W
ith inductive load ohmic share min. 25 Ω/mH.
48
VEGAPULS
67 • 4 … 20
mA/HART four-wire
10 S
upplement
32939
-EN
-100514