beautypg.com

VEGA VEGAPULS 67 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART four-wire User Manual

Page 19

background image

Socket diameter d

Socket length h

80

mm

300

mm

100

mm

400

mm

150

mm

500

mm

Socket diameter d

Socket length h

3"

11.8

in

4"

15.8

in

6"

19.7

in

Tip:
I

n new facilities it is useful to incline the vessel socket in the direction

of the outlet. False reflections from the vessel wall are thus reduced
and measurement all the way down to the bottom of the conical outlet
is possible.

Fig. 12: Alignment in silos

T

he silo walls of multiple chamber silos are often made of profile walls,

like e.g. profile sheeting, to ensure the required stability. If the radar
sensor is mounted very close to a heavily structured vessel wall,
substantial interfering reflections can be generated. Hence the sensor
should be mounted at a large distance from the separating wall.

Mounting in multiple
chamber silo

VEGAPULS

67 • 4 … 20

mA/HART four-wire

19

4 M

ounting

32939

-EN

-100514