Fig. 9: Proposal for installation after orientation VEGAPULS 68

The angle of inclination depends on the vessel dimensions. It can be
easily checked with a suitable level or water leve on the sensor.

Tip:
VEGA recommends the adjusting aid from VEGA line of accessory.
This is a round, direction-independent water level which is simply
place to the sensor housing.

The following chart specifies the distance "a" between installation
position and vessel centre dependent on the measuring distance for
inclination angles of 2° … 10°.

Distance d
(m)

10°

2

0.1

0.1

0.2

0.3

0.4

4

0.1

0.3

0.4

0.6

0.7

6

0.2

0.4

0.6

0.8

1.1

8

0.3

0.6

0.8

1.1

1.4

10

0.3

0.7

1.1

1.4

1.8

15

0.5

1.0

1.6

2.1

2.6

20

0.7

1.4

2.1

2.8

3.5

25

0.9

1.7

2.6

3.5

4.4