VEGA VEGAVIB 61 - two-wire User Manual
Page 33
1
2
3
-50°C
(-58°F)
50°C
(122°F)
40°C
(104°F)
-40°C
(-40°F)
80°C
(176°F)
0°C
(32°F)
100°C
(212°F)
150°C
(302°F)
200°C
(392°F)
250°C
(482°F)
Fig. 49: Ambient temperature - Process temperature
1
Process temperature
2
Ambient temperature
3
Temperature range with temperature adapter
Density
-
Standard
>
0.05 g/cm³ (0.002 lbs/in³)
-
adjustable
>
0.02 g/cm³ (0.0007 lbs/in³)
Granular size
no limitation
3)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
4)
-
Single chamber housing
l
1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5
Spring-loaded terminals
for wire cross-section up to 1.5 mm² (AWG 16)
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
-
Single chamber housing
l
1 x IP 68 cable gland M20 x 1.5; 1 x blind
stopper M20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
Connection cable
-
Wire cross-section
0.5 mm² (AWG 20)
3)
max. 20 mm (0.8 in) with product density < 0.05 g/cm³ (0.002 lbs/in³).
4)
Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.
VEGAVIB
61 • - two-wire
33
9 Supplement
29268
-
EN
-120418