beautypg.com

VEGA VEGAVIB 62 Cable shortening set User Manual

Page 11

background image

11 Pull the cut cable (9) out of the upper part of the oscillator

(19).
Keep all parts for mounting.

7

9

12

10

Fig. 7: Sever the suspension cable (12) with a bolt cutter

7

Cable clamp

9

Cable

10 Perforated disc

12 Suspension cable

12 Cut the suspension cable (12) with a bolt cutter and keep

the perforated disc (10) for mounting.

13 Clean the remaining cable of the sensor (9) of oil and

grease and rub it off with talcum.
The old cable crimping cannot be used anymore and must

be correctly disposed of.

6

18

17

9

8

14

15

16

19

10

7

100 mm

(3

15

/

16

")

Fig. 8: Slide the parts onto the cable

6

Pins (4 pcs.)

7

Cable clamp

8

Mounting boss

9

Cable

10 Perforated disc

14 Pressure screw

15 Pressure ring

16 Rubber wrapping

17 Washer

18 Rubber rings (4 pcs.)

19 Upper part of the oscillator

VEGAVIB 62 • Cable shortening set

11

Mounting

30097

-EN

-080310