Process conditions
Parameter
Limit level of solids
Process pressure
-1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psi)
VEGAVIB 66 of 316L
-20 … +80 °C (-4 … +176 °F)
Density
- Standard
>0.02 g/cm³ (>0.0007 lbs/in³)
- adjustable
>0.008 g/cm³ (>0.0003 lbs/in³)
Electromechanical data
Cable entry/plug (dependent on the version)
- Single chamber housing
l
1x cable entry M20x1.5 (cable-ø 5 … 9 mm),
1x blind stopper M20x1.5, attached 1x
cable entry M20x1.5
or:
l
1x cable entry ½ NPT, 1x blind stopper
½ NPT, 1x cable entry ½ NPT
or:
l
1x plug M12x1, 1x blind stopper M20x1.5
Spring-loaded terminals
for wire cross-section up to 1.5 mm²
(0.0023 in²)
Adjustment elements
Mode switch
- min.
min. detection or dry run protection
- max.
max. detection or overfill protection
Voltage supply
Supply voltage
20 … 253 V AC, 50/60 Hz, 20 … 253 V DC
Domestic current requirement
approx. 3 mA (via load circuit)
Load current
- min.
10 mA
- max.
400 mA (at I >300 mA the ambient temperature
can be max. 60 °C/140 °F) max. 4 A up to
40 ms
Electrical protective measures
Protection
IP 66/IP 67
Overvoltage category
III
Supplement
VEGAVIB 66 - with contactless electronic switch
29
29290
-EN
-060508