3

Fig. 4: Filling in the center, emptying laterally

1

VEGAVIB 66

2

Emptying opening

3

Filling opening

The vibrating element should protrude into the vessel to avoid

buildup. For that reason, avoid using mounting bosses for

flanges and screwed fittings. This is mainly applicable for

adhesive products.

If VEGAVIB 66 is mounted in the filling stream, unwanted

switching signals may be generated. Mount VEGAVIB 66 at a

location in the vessel where no disturbing influence from e.g.

filling openings, agitators etc. can occur.

Socket

Inflowing material

VEGAVIB 66 - with contactless electronic switch