VEGA VEGASWING 61 - transistor (NPN-PNP) User Manual
Page 25
25
9 Supplement
VEGASWING 61 • - transistor (NPN/PNP)
29225-EN-130409
Ʋ Standard
R
a
3 µm (1.18
-4
in)
Ʋ Hygienic version (3A)
R
a
< 0.8 µm (3.15
-5
in)
Ʋ Hygienic version (3A)
R
a
< 0.3 µm (1.18
-5
in)
Process fittings
Ʋ Pipe thread, cylindrical (DIN 3852-A) G¾, G1 A
Ʋ American pipe thread, conical
(ASME B1.20.1)
¾ NPT, 1 NPT
Ʋ Flanges
DIN from DN 25, ANSI from 1"
Ʋ hygienic fittings
Bolting DN 40 PN 40, Clamp 1" DIN 32676
ISO 2852/316L, Clamp 1½" PN 10 DIN 32676
ISO 2852/316L, conus DN 25 PN 40, Tuchenhagen
Varivent DN 50 PN 10
Max. torque - process fitting
Ʋ Thread G¾, ¾ NPT
75 Nm (55 lbf ft)
Ʋ Thread G1, 1 NPT
100 Nm (73 lbf ft)
Output variable
Output
Floating transistor output, permanently shortcircuit-proof
Load current
< 400 mA
Voltage loss
< 1 V
Turn-on voltage
< 55 V DC
Blocking current
< 10 µA
Modes (switchable)
Ʋ A
Max. detection or overflow/overfill protection
Ʋ B
Min. detection or dry run protection
Accuracy (according to DIN EN 60770-1)
Reference conditions and actuating variables according to DIN EN 61298-1
Ʋ Ambient temperature
+18 … +30 °C (+64 … +86 °F)
Ʋ Relative humidity
45 … 75 %
Ʋ Air pressure
860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psig)
Ʋ Product temperature
+18 … +30 °C (+64 … +86 °F)
Ʋ Product density
1 g/cm³ (0.036 lbs/in³) (water)
Ʋ Product viscosity
1 mPa s
Ʋ Superimposed pressure
0 kPa
Ʋ Sensor installation
Vertically from top
Ʋ Density selection switch
> 0.7 g/cm³
Measuring accuracy
Deviation
± 1 mm (0.04 in)